
{"id":16857,"date":"2025-04-29T09:16:37","date_gmt":"2025-04-29T09:16:37","guid":{"rendered":"https:\/\/lenard.tech\/?post_type=product&#038;p=16857"},"modified":"2025-04-29T09:32:56","modified_gmt":"2025-04-29T09:32:56","slug":"une-en-8631996","status":"publish","type":"product","link":"https:\/\/lenard.tech\/en\/producto\/une-en-8631996\/","title":{"rendered":"UNE EN 863:1996"},"content":{"rendered":"<section class=\"wpb-content-wrapper\"><p>[vc_row woodmart_css_id=&#8221;64770fff47a07&#8243; responsive_spacing=&#8221;eyJwYXJhbV90eXBlIjoid29vZG1hcnRfcmVzcG9uc2l2ZV9zcGFjaW5nIiwic2VsZWN0b3JfaWQiOiI2NDc3MGZmZjQ3YTA3Iiwic2hvcnRjb2RlIjoidmNfcm93IiwiZGF0YSI6eyJ0YWJsZXQiOnt9LCJtb2JpbGUiOnt9fX0=&#8221; mobile_bg_img_hidden=&#8221;no&#8221; tablet_bg_img_hidden=&#8221;no&#8221; woodmart_parallax=&#8221;0&#8243; woodmart_gradient_switch=&#8221;no&#8221; woodmart_box_shadow=&#8221;no&#8221; wd_z_index=&#8221;no&#8221; woodmart_disable_overflow=&#8221;0&#8243; row_reverse_mobile=&#8221;0&#8243; row_reverse_tablet=&#8221;0&#8243;][vc_column][vc_column_text woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]<\/p>\n<div class=\"QFw9Te BLojaf\">\n<p><strong>STANDARD <\/strong><strong>UNE EN 863: 1996 PUNCTUARE RESISTANCE<\/strong><\/p>\n<\/div>\n<div class=\"QcsUad BDJ8fb BLojaf sMVRZe wneUed\">\n<div class=\"XL3Kf\">\n<div class=\"a8FIud X0rvP\">\n<div data-show-delay-ms=\"250\" data-append-to-body=\"false\" data-propagate-tooltip-mouseover-events=\"true\" data-anchor-corner=\"bottom-end\" data-enable-skip-handler=\"false\" data-popup-corner=\"top-end\">\n<div class=\" B2mKhd eQGGme xGUN1\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs title_tag=&#8221;h3&#8243; section_title_tag=&#8221;h3&#8243; style=&#8221;modern&#8221; color=&#8221;white&#8221; active_section=&#8221;1&#8243; no_fill_content_area=&#8221;true&#8221;][vc_tta_section title=&#8221;PRINCIPLE&#8221; tab_id=&#8221;1685522856916-22531c7c-aaf1&#8243;][vc_column_text woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]Puncture resistance is expressed as the maximum force required to punch the sample at a specific speed.<\/p>\n<ul>\n<li>4 samples must be taken for testing with a minimum diameter of 50 mm.<\/li>\n<li>The testing apparatus is the CRE type tensile testing machine according to EN 10002-2<\/li>\n<li>The test punch must be made of steel with a minimum hardness of 60 HRC and with the dimensions described in the standard.<\/li>\n<li>The jaws will prevent the specimen from slipping during the test. They must be made up of two flat steel plates at least 10mm thick with a hole in the centre of 20 \u00b1 0.5mm and 4 fastening bolts.<\/li>\n<li>Specimens must be conditioned according to ISO 2231 (temperature 20 \u00b1 2 \u00b0C and a relative humidity of 65 \u00b1 5%)<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;PROCEDURE&#8221; tab_id=&#8221;1734424905890-4decb381-a629&#8243;][vc_column_text woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]<\/p>\n<ul>\n<li>The specimen must be placed between the two jaws with the outer surface exposed to the punch.<\/li>\n<li>Tighten the bolts to prevent slippage or deterioration of the specimen.<\/li>\n<li>Place the specimen and jaws on the testing machine.<\/li>\n<li>Advance the punch towards the specimen at 100 \u00b1 10mm\/min. If the punch fails to penetrate the specimen after a 25 mm movement, the test is considered completed.<\/li>\n<li>Record for each test the maximum force (N) to drill the specimen.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;RESULTS&#8221; tab_id=&#8221;1734424931257-854d2da4-7f6d&#8221;][vc_column_text woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]The arithmetic mean of the maximum force obtained in the 4 specimens (N) will be reported.[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p><strong>PUNCTURE RESISTANCE<\/strong><\/p>\n","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"product_cat":[883],"product_tag":[3092,2368,1638],"class_list":["post-16857","product","type-product","status-publish","hentry","product_cat-normative","product_tag-863-en","product_tag-alta-resistencia-en","product_tag-perforacion-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/lenard.tech\/en\/wp-json\/wp\/v2\/product\/16857","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lenard.tech\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lenard.tech\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lenard.tech\/en\/wp-json\/wp\/v2\/comments?post=16857"}],"wp:attachment":[{"href":"https:\/\/lenard.tech\/en\/wp-json\/wp\/v2\/media?parent=16857"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lenard.tech\/en\/wp-json\/wp\/v2\/product_cat?post=16857"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lenard.tech\/en\/wp-json\/wp\/v2\/product_tag?post=16857"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}