RIS-3279-TOM HV
Back to products
Placeholder
UNE-EN 4920

UNE-EN 61482-1-2:2014

BOX TEST

  • APPLICATION
  • DEFINITIONS
  • PROCEDURE FOR MATERIALS
  • PROCEDURE FOR GARMENTS
  • INTERPRETATION OF RESULTS

APPLICATION

This part of the standard indicates the procedure for testing heat and flame resistant materials and clothing when there is a risk of electric arc using a limited, directed electric arc to classify the material and clothing into 2 protection classes prescribed in EN 61482-1-1.

DEFINITIONS

-Arc Intensity Iarc: Actual intensity flowing in the circuit during the duration of the arc expressed in effective kA.

-Warc arc energy: The sum of the instantaneous arc tension multiplied by the instantaneous arc intensity multiplied by the time increments of the arc duration expressed in kJ or kW·s.

-Arc Interval: Distance between the arc electrodes

-Thermal protection against arcing: for garments, the thermal performance of arc is obtained by evaluating the burning time, formation of holes, fusion and operation of fasteners as well as accessories.

-Arc tension: expressed in V.

-Peak delta temperature ΔTp: Difference between the maximum temperature and the initial temperature of the sensor during the exposure time expressed in ºC.

-Incident energy of direct exposure, Ei0: Thermal energy or incident received by a calorimeter which has been emitted by the electric arc expressed in kJ/m2 or kW·s/m2 (cal/cm2).

-Electric arc: Gaseous conduction in which electrons are the majority of the charge carriers produced by primary electronic emission.

-Thermal flow: It is the amount of energy transmitted per unit area and time expressed in kW/m2.

-Incident energy, Ei: Total heat received per unit area as a result of an electric arc expressed in kJ/m2 or kW·s/m2 (cal/cm2).

-Expected short-circuit current: The predicted current that will flow when the arc electrodes are connected by a conductor expressed in kA rms.

-Stoll curve: It is an empirical model for predicting 2nd degree burns of the skin by relating the amount of thermal energy transferred to the humble tissue and the time of exposure.

-Test intensity, Iclass: Intensity of the expected short circuit expressed in kA rms.

-Time to peak delta temperature, tmax: Time expressed in seconds, from the start of arc priming to reach peak delta temperature.

-Transmitted energy, Eit: Incident energy received by a calorimeter when testing clothing or material expressed in kJ/m2 or kW·s/m2 (cal/cm2).

PROCEDURE FOR MATERIALS

  • The amount of heat energy transferred by flat materials during and after exposure to the electric arc is measured.These data will be used to evaluate the incidence of second-degree burns using the Stoll curve.The distance between the electrode and the test plate shall be 300 ± 5 mm and the interval between the electrodes shall be 30 ± 1 mm.

    The test plate shall be made of a non-conductive heat-resistant material of 400 x 400 ± 10 mm with a minimum thickness of 10 mm.

    The sample to be tested will be 500 mm ± 10 mm long and 500 ± 10 mm wide cut according to the length and width of the material. 4 samples will be analyzed. If one of them does not meet the acceptance criteria, a fifth sample will be tested. No more than 5 samples can be taken.

    Samples must be pre-treated by pre-cleaning according to the manufacturer’s instructions or 5 cycles of washing and drying. Then they must be conditioned between 18 – 28 ºC with relative humidity of 45 – 75 % at least 24 h.

    The specimens will be folded around the test plate in a flat position. The material will be fixed on the back of the plate ensuring optimal contact with the plate without the presence of air between the sample and the calorimeter.

PROCEDURE FOR GARMENTS

  • Heat fluxes will not be measured in this test.A dummy should be used for the test of garments where the upper part corresponds to the torso and should be positioned in such a way that the midpoint of the sternum area is horizontally and vertically aligned with the interval of the electrodes.The distance between the manikin and the electrode should be 300 ± 5 mm.

    If the test is for bottoms, a dummy with hips and legs may be used using the center of the electrode range at the crotch.

    If other parts of the garments are of interest, it can be tested on a flat test plate.

    The circuit must have the ability to give a near-constant source of alternating voltage and short-circuit current. 50 and 60 Hz are allowed for alternating current.

    A fuse wire connected to the ends of the opposing electrodes should be used and this will be consumed during the test. This wire will be made of copper with a maximum diameter of 0.5 mm.

    Characteristics of the goal:

    -Test voltage: 400 V ± 5% alternating current

    -Iclasse test intensity: for class 1, 4 kA ± 5 % and for class 2, 7 kA ± 5 %

    -Arc duration: 500ms ± 5%

    -Frequency: 50 ± 0.1 Hz or 60 ± 0.12 Hz

    The sample rate must be at least 5 kHz

    Temperature should be sampled at least 5 ms per channel for 30 s at 0.1 °C resolution.

    The garment must be made with all its standard inclusions, zippers and pockets. This garment will be pre-treated according to the manufacturer’s instructions based on standardized processes. If no instructions are specified, the test will be carried out after 5 washing and drying cycles.

    The sample should be conditioned for at least 24 hours at 18–28 ºC with a relative humidity between 45–75% and tested within 5 minutes after conditioning.

    At least 1 garment sample will be tested. Additional samples will be required in case the arc energy during the discharges is out of range.

    The test shall be carried out at an ambient temperature between 15 and 35 °C with a relative humidity of 25 to 75 %.

INTERPRETATION OF RESULTS

Incident energy Ei: it will be calculated by multiplying the peak delta temperature by the sensor constant 5.52 kJ/m2 ºC. The incident energy of direct exposure Ei0 and the 4 values of the transmitted energy Eit must be determined, as well as the mean value of the 4 Eit values and their 95 % confidence interval

Sensor response to the Stoll curve: the Stoll curve must be superimposed on the trace of the 4 pairs of values (Eit and time to the peak delta tmax) and also on the trace of the 4 heat curves Eit(t) of the incident energy transmitted.

A visual inspection will be performed once the samples are cool.

The test will be considered a PASS when:

-The material of the garment has passed the test for materials

-The pledge complies: the burning time is less than or equal to 5 s; there is no fusion through the inner side; There are no holes larger than 5 mm in the innermost layer. Accessories will not have any negative influence on the results.

 

 

Compare
Add to wishlist
Category: Normative

Development and innovation of technical fabrics: THAT IS LENARD. Founded in 1996 by people with extensive experience in the textile sector, it has stood out since its beginning for a strong commitment to innovation and personal protection through the use of new fibers and manufacturing methods with the most advanced technology. Its wide range of fabrics offers protection for different sectors, complying with the requirements established by international certifications.

Latest news
  • Newsletter June 2025
    26 de June de 2025 No Comments
  • Newsletter May 2025 Part II
    27 de May de 2025 No Comments
  • Newsletter May 2025
    13 de May de 2025 No Comments
  • Newsletter April 2025
    14 de April de 2025 No Comments

LENARD BCN, S.L.

Avda. Aragón nº37 - 22520 Fraga (Huesca)
info@lenard.tech
How to get

CENTRO OPERATIVO / HEADQUARTERS

Pol. Ind. Sot dels Pradals
C/ Sabadell, 3
08500 - Vic (Barcelona) Spain
How to get

LENARD MX, S de RL de CV

Rio Atoyac 30. Parque Industrial Empresarial Cuautlancingo
Cuautlancingo, 72730 Puebla (México)
+52 222 2319969
jisanchez@lenard.tech
How to get

LENARD USA CORP

2655-Lejeune Rd., Suite 810
Coral Gables, FL. 33134 (USA
+52 222 2319969
fcastejon@lenard.tech
How to get

LENARD Diseño web: Infoactiva't.
Aviso legal | Política de privacidad | Política de cookies
  • Start
  • About us
  • Products
    • Fabrics
      • Europe Catalog
      • America Catalog
    • ECO products
    • Accessories
    • Knitwear
  • Regulation
  • Sustainability
  • Vídeos
  • News
    • Fairs
    • New products
    • Newsletter
  • contact
  • English
  • German
  • Spanish
  • Wishlist
  • Compare
  • Login / Register
Start typing to see products you are looking for.

We are using cookies to give you the best experience on our website.

You can find out more about which cookies we are using or switch them off in .

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.

3rd Party Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.

Please enable Strictly Necessary Cookies first so that we can save your preferences!